임플랜트 나사선 경사각이 치조골 응력 분포에 미치는 영향

' 임플랜트 나사선 경사각이 치조골 응력 분포에 미치는 영향' 의 주제별 논문영향력
논문영향력 선정 방법
논문영향력 요약
주제
  • 치과의학, 이비인후과학, 안과학
동일주제 총논문수 논문피인용 총횟수 주제별 논문영향력의 평균
906 1

0.1%

' 임플랜트 나사선 경사각이 치조골 응력 분포에 미치는 영향' 의 참고문헌

  • Visualizationand initial characterization of the titani-um boundary of the bone-implant interfaceof osseointegrated implants
    151 ~ 60 [1992]
  • Three-dimentional finiteelement analysis of stress-distributionaround single tooth implants as a functionof bony support, prothesis type, and load-ing during function
    Three-dimentional finiteelement analysis of stress-distributionaround single tooth implants as a functionof bony support [1996]
  • Three-dimensional stress distribution around a dental implant at different stages of interface development
    155 ~ 159 [1983]
  • Numerical investi-gation of the influence of the implantshape on stress distribution in the jaw bone
    유경희 [1989]
  • Mechanical loading of Branemark implants affects interfacial bone modeling and remodeling
    송혜림 [1994]
  • Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys
    석용원 [1996]
  • Influence of bonequality on stress distribution for endosseous implants
    박원달 Influence of bonequality on stress distribution for endosseous implants [1997]
  • Histologicstudies of a human mandible supporting animplant denture
  • Forces and489moments on Brnemark implants
    김태웅 [1989]
  • Finite element analysis of six endosseous implants
    김진모 [1990]
  • Finite element analysis of four-abutment Hader bar designs
    김진모 [1993]
  • Evaluation of results of treat-ment with osseointegrated implant bythe Swedish National Board of Healthand Welfare
  • Evaluating parameters of osseointegrated dental implants using finite element analysis-a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction
    김용주 Evaluating parameters of osseointegrated dental implants using finite element analysis-a two-dimensional comparative study examining the effects of implant diameter [1998]
  • Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element: a finite element gtress analysis
    강민지 [1992]
  • Bone-metal interface in osseointegration
    Snyder [1987]
  • Biomaterial and biomechan-ics in dental implant design
    Sears [1988]
  • Alternative materials for three en-dosseous implants
  • A finite element survey of eleven endosseous implants
    Kotulak [1990]
  • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    Kaplan A 15 year study of osseointegrated implants in the treatment of the edentulous jaw [1981]