광원에 따른 수종의 치면열구전색제로부터 용리되는모노머에 관한 연구

논문상세정보
' 광원에 따른 수종의 치면열구전색제로부터 용리되는모노머에 관한 연구' 의 주제별 논문영향력
논문영향력 선정 방법
논문영향력 요약
주제
  • 부인과, 산과학, 소아과학
동일주제 총논문수 논문피인용 총횟수 주제별 논문영향력의 평균
103 1

0.0%

' 광원에 따른 수종의 치면열구전색제로부터 용리되는모노머에 관한 연구' 의 참고문헌

  • Time-related bisphenol-A content and estrogenic activity in saliva samples collected in relation to placement of fissure sealants 3
    120 ~ 125 [1999]
  • The effect of post-cure heating on residual,unreacted monomer in a commercial resin composite 16
    244 ~ 247 [2000]
  • The effect of curing light intensity and test temperature on the dynamic mechanical properties of two polymer composites 26
    635 ~ 639 [1999]
  • Stability of bisphenol A,triethylene-glycol dimethacrylate,and bisphenol A dimethacrylate in whole saliva 18
    128 ~ 135 [2002]
  • Residual monomer and pendant methacryloyl group in light-cured composite resins 11
    177 ~ 188 [1992]
  • Rate of elution of leachable components from composites 6
    282 ~ 287 [1990]
  • Porosity of pit and fissure sealants 18
    213 ~ 220 [1991]
  • Polymerisation characteristics of resin composites polymerised with different curing units 32
    479 ~ 488 [2004]
  • Pharmacokinetics of bisphenol A released from a dental sealant 131
    51 ~ 58 [2000]
  • Minimizing patients' exposure to uncured components in a dental sealant 130
    1751 ~ 1757 [1999]
  • Light-activated restorative materials:a method of determining effective radiation times 23
    210 ~ 218 [1996]
  • Light intensity effects on resin-composite degree of conversion and shrinkage strain 16
    292 ~ 296 [2000]
  • Light emitting diode (LED) polymerisation of dental composites
    1379 ~ 1385 [2000]
  • Influence of curing light intensity on marginal adaptation of composite fillings 72
    [1993]
  • In vitro elution of leachable components from dental sealants 128
    1517 ~ 1523 [1997]
  • Identification and characterization of estrogen-like components in commercial resin-based dental restorative materials 3
    107 ~ 113 [1999]
  • HPLC analysis of dental resin composites components 47
    374 ~ 378 [1999]
  • Factors affecting cure at depth within light activated resin composites 6
    91 ~ 95 [1993]
  • Estrogenicity of resin-based composites and sealants used in dentistry 104
    298 ~ 305 [1996]
  • Elution of TEGDMA and BisGMA from a resin and a resin composite cured with halogen or plasma light 108
    341 ~ 345 [2000]
  • Effects of various resin composite monomers and extracts on two caries-associated micro-organisms in vitro
    60 ~ 67 [1998]
  • Effects of various light curing methods on the leachability of uncured substances and hardness of a composite resin 31
    258 ~ 264 [2004]
  • Effects of unpolymerized resin components on the function of accessory cells derived from the rat incisor pulp 74
    1162 ~ 1167 [1995]
  • Effect of plasma arc curing on the microleakage of class V resin-based composite restorations 13
    121 ~ 122 [2000]
  • Effect of light wavelength on polymerization of light cured resins 16
    60 ~ 73 [1997]
  • Effect of light intensity on polymerization of light-cured composite resins 13
    198 ~ 205 [1994]
  • Effect of light intensity and exposure duration on cure of resin composite
    김명화 26 ~ 32 [1994]
  • Effect of diluent monomer on the physical properties of bis-GMA-based composites 60
    983 ~ 989 [1981]
  • Determination of residual monomers in dental pit and fissure sealants using food
    oral simulation fluids 1115 ~ 1118 [2000]
  • Determination of bisphenol A and related aromatic compounds released from bis-GMA-based composites and sealants by high performance liquid chromatography 108
    21 ~ 27 [2000]
  • Depth of cure and compressive strength of dental composites cured with blue light emitting diodes
    교육인적자원부 41 ~ 47 [2000]
  • Cytotoxicity of 35 dental resin composite monomers
    additives in permanent 3T3 and three human primary fibroblast cultures 41 474 ~ 480 [1998]
  • Correlation of parameter used to estimate monomer conversion in a light-cured composite 67
    932 ~ 937 [1988]
  • Composite conversion and temperature rise using a conventional,plasma arc,and an experimental blue LED curing unit 29
    662 ~ 667 [2002]
  • Comparison of halogen,plasma and LED curing units 29
    287 ~ 294 [2004]
  • Comparison of depth of polymerization evaluation method for photo-activated composite 63
    1095 ~ [1984]
  • Comparison between a plasma arc light source and conventional halogen curing units regarding flexural strength, modulus, and hardness of photoactivated resin composites 4
    140 ~ 147 [2000]
  • Characterization of three light sources Study of their efficiency
    1165 ~ 1170 [2003]
  • Characterization of resin composites polymerized with plasma arc curing units 16
    330 ~ 336 [2000]
  • Bisphenol-A content of resin monomers and related degradation products 3
    114 ~ 119 [1999]
  • A study of component release from resin pit and fissure sealants in vitro 13
    98 ~ 102 [1997]