임플란트 단일 치아 수복 시 수직 침하와 인접치와의 위치 변화: 증례 보고

논문상세정보
' 임플란트 단일 치아 수복 시 수직 침하와 인접치와의 위치 변화: 증례 보고' 의 주제별 논문영향력
논문영향력 선정 방법
논문영향력 요약
주제
  • Axial displacement
  • In vivo
  • Infraposition
  • internal connection
  • intraoralscan
  • invivo
  • 구강 스캔
  • 내부연결형
  • 수직침하
  • 저위
동일주제 총논문수 논문피인용 총횟수 주제별 논문영향력의 평균
108 0

0.0%

' 임플란트 단일 치아 수복 시 수직 침하와 인접치와의 위치 변화: 증례 보고' 의 참고문헌

  • Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection
    Kim KS [2011]
  • Relationship between implant preload and screw loosening on implant-supported prostheses
    Siamos G [2002]
  • Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
  • Occlusal migration of teeth adjacent to implant prostheses in adults : A long-term study
    Polymeri A [2020]
  • Mechanics of the tapered interference fit in dental implants
    Bozkaya D [2003]
  • Mechanics of the implant-abutment connection : an 8-degree taper compared to a butt joint connection
    Merz BR [2000]
  • Loads and designs of screw joints for single crowns supported by osseointegrated implants
    Jörnéus L [1992]
  • In vitro differences of stress concentrations for internal and external hex implant-abutment connections : a short communication
    Maeda Y [2006]
  • Fixed implant-supported prostheses in the edentulous maxilla. A five-year follow-up report
    Jemt T [1994]
  • Fatigue resistance of two implant/abutment joint designs
    Khraisat A [2002]
  • Effect of cyclic loading on axial displacement of abutment into implant with internal tapered connection: a pilot study
    설현우 [2013]
  • Digital evaluation of axial displacement by implant-abutment connection type: an in vitro study
    김성준 [2018]
  • Comparison of external and internal implant-abutment connections for implant supported prostheses. A systematic review and meta-analysis
    Lemos CAA [2018]
  • Axial displacements in external and internal implant-abutment connection
    Lee JH [2014]
  • Axial displacement of abutments into implants and implant replicas, with the tapered cone-screw internal connection, as a function of tightening torque
    Dailey B [2009]
  • A quantitive analysis of settling effect in internal tapered connection implants after cyclic loading using 858 Bionix II
    Hyeon JM [2015]
  • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    Adell R [1981]