안내 후방인공수정체삽입술 렌즈 직경에 따른 중심 볼트 결과

논문상세정보
' 안내 후방인공수정체삽입술 렌즈 직경에 따른 중심 볼트 결과' 의 주제별 논문영향력
논문영향력 선정 방법
논문영향력 요약
주제
  • Vaulting
  • White-to-wh
  • anterior chamber depth
  • implantablecollamerlens
동일주제 총논문수 논문피인용 총횟수 주제별 논문영향력의 평균
46 0

0.0%

' 안내 후방인공수정체삽입술 렌즈 직경에 따른 중심 볼트 결과' 의 참고문헌

  • Ultrasound biomicroscopy examination of posterior chamber phakic intraocular lens position
  • Optimization of an implantable collamer lens sizing method using high-frequency ultrasound biomicroscopy
    Kojima T [2012]
  • Long-term evaluation of the central vault after phakic Collamer(R)lens(ICL)implantation using OCT
    Alfonso JF [2012]
  • Long-term changes in posterior chamber phakic intraocular collamer lens vaulting in myopic patients
  • Implantable contact lens for moderate to high myopia : relationship of vaulting to cataract formation
    Gonvers M [2003]
  • Implantable collamer posterior chamber intraocular lenses : a review of potential complications
    Fernandes P [2011]
  • Four-year follow-up of posterior chamber phakic intraocular lens implantation for moderate to high myopia
    Kamiya K [2009]
  • Factors affecting vaulting after implantable collamer lens implantation
    Kamiya K [2009]
  • Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using artemis VHF digital ultrasound
  • Correlation between preoperative biometry and posterior chamber phakic Visian Implantable Collamer Lens vaulting
    Lee DH [2012]
  • Comparison over time of vault in Chinese eyes receiving implantable contact lenses with or without a central hole
    Cao X [2016]
  • Comparison of postoperative vault height predictability using white-to-white or sulcus diameter-based sizing for the visian implantable collamer lens
  • Clinical results of posterior chamber phakic intraocular lens implantation in eyes with low anterior chamber depth
    Lim DH [2014]
  • Changes in vaulting and the effect on refraction after phakic posterior chamber intraocular lens implantation
    Kamiya K [2009]
  • Causes of phakic implantable collamer lens explantation/exchange at King Khaled Eye Specialist Hospital
  • Buffering zone of implantable Collamer lens sizing in V4c
    Nam SW [2017]
  • Anterior segment optical coherence tomography angle and vault analysis after toric and non-toric implantable collamer lens V4c implantation in patients with high myopia
  • Anterior chamber changes after implantable collamer lens implantation in high myopia using pentacam : a prospective study
  • Age-related behavior of posterior chamber lenses in myopic phakic eyes during accommodation measured by anterior segment partial coherence interferometry
    Lege BA [2006]