Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types

논문상세정보
' Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types' 의 주제별 논문영향력
논문영향력 선정 방법
논문영향력 요약
주제
  • Cochlear implant electrode arrays · Lateral wall · Perimodiolar · ECAP · Mapping
동일주제 총논문수 논문피인용 총횟수 주제별 논문영향력의 평균
1 0

0.0%

' Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types' 의 참고문헌

  • Threshold, comfortable level and impedance changes as a function of electrode-modiolar distance
    Saunders E [2002]
  • The nucleus 24 contour cochlea implant system: adult clinical trial results
  • The effects of preprocessing strategies for pediatric cochlear implant recipients
  • Ranjith R. Electrophysiological correlates of behavioral comfort levels in cochlear implantees: a prospective study
  • Psychophysics of a prototype peri-modiolar cochlear implant electrode array
    Cohen LT [2001]
  • Probing the electrode-neuron interface with focused cochlear implant stimulation
    Bierer JA [2010]
  • Potential distributions and neural excitation patterns in a rotationally symmetric model of the electrically stimulated cochlea
    Frijns JH [1995]
  • Popecki B. Eletrical compound action potentials recorded with automated neural response telemetry: threshold changes as a function of time and electrode position
    Spivak L [2011]
  • Perimodiolar electrodes in cochlear implant surgery
  • Partial deafness treatment with the nucleus straight research array cochlear implant
  • Optimizing cochlear implant speech performance
    Skinner MW [2003]
  • Optimal electrode design: straight versus perimodiolar
    Gibson P [2016]
  • Modiolar coiling, electrical thresholds, and speech perception after cochlear implantation using the nucleus contour advance electrode with the advance off stylet technique
    Huang TC [2006]
  • Modeling the electrode-neuron interface of cochlear implants: effects of neural survival, electrode placement, and the partial tripolar configuration
    Goldwyn JH [2010]
  • Influence of evoked compound action potential on speech perception in cochlear implant users
    Guedes MC [2007]
  • Impact of electrode design and surgical approach on scalar location and cochlear implant outcomes
    Wanna GB [2014]
  • Imaging of electrode position in relation to electrode functioning after cochlear implantation
  • Imaging evaluation of electrode placement and effect on electrode discrimination on different cochlear implant electrode arrays
  • Hearing and deafness: an introduction for health and education professionals
    Paul PV [2011]
  • Evolution of cochlear implant arrays result in changes in behavioral and physiological response in children
    Gordin A [2009]
  • Electrophysiologic channel interaction, electrode pitch ranking, and behavioral threshold in straight versus perimodiolar cochlear implant electrode arrays
    Hughes ML [2006]
  • Electrically evoked compound action potentials are different depending on the site of cochlear stimulation
  • Electrical stimulation of the auditory nerve: the effect of electrode position on neural excitation
    Shepherd RK [1993]
  • Effect of cochlear implant electrode array design of auditory nerve and behavioral response in children
  • Considerations for design of future cochlear implant electrode arrays: electrode array stiffness, size, and depth of insertion
    Rebscher SJ [2008]
  • Cochlear implantation in inner ear malformations--a review article
  • Activity-dependent develop mental plasticity of the auditory brain stem in children who use cochlear implants
    Gordon KA [2003]
  • A re-evaluation of the relation between physiological channel interaction and electrode pitch ranking in cochlear implants
    Hughes ML [2008]