Comparison of Chest Pain Protocols for Electrocardiography-Gated Dual-Source Cardiothoracic CT in Children and Adults: The Effect of Tube Current Saturation on Radiation Dose Reduction

구현우 2018년
논문상세정보
    • 저자 구현우
    • 제어번호 105082222
    • 학술지명 Korean Journal of Radiology
    • 권호사항 Vol. 19 No. 1 [ 2018 ]
    • 발행처 대한영상의학회
    • 자료유형 학술저널
    • 수록면 23-31
    • 언어 English
    • 출판년도 2018
    • 등재정보 KCI등재
    • 소장기관 영남대학교 의료원 의학도서관 충남대학교 의학도서관
    • 판매처
    유사주제 논문( 0)

' Comparison of Chest Pain Protocols for Electrocardiography-Gated Dual-Source Cardiothoracic CT in Children and Adults: The Effect of Tube Current Saturation on Radiation Dose Reduction' 의 참고문헌

  • Tube current reduction in pediatric non-ECGgated heart CT by combined tube current modulation
    Goo HW [2006]
  • Triple-rule-out dual-source CT angiography of patients with acute chest pain: dose reduction potential of 100 kV scanning
    Krissak R [2012]
  • The utility of cardiac CT beyond the assessment of suspected coronary artery disease
    Kakouros N [2012]
  • The influences of tube voltage and scan direction on combined tube current modulation: a phantom study
    Goo HW [2006]
  • Semiautomatic three-dimensional CT ventricular volumetry in patients with congenital heart disease: agreement between two methods with different user interaction
    Goo HW [2015]
  • Saving dose in triple-rule-out computed tomography examination using a high-pitch dual spiral technique
    Sommer WH [2010]
  • Potential for radiation dose savings in abdominal and chest CT using automatic tube voltage selection in combination with automatic tube current modulation
    Mayer C [2014]
  • Left ventricle volume measured by cardiac CT in an infant with a small left ventricle : a new and accurate method in determining uni-or biventricular repair
    Kim HJ [2013]
  • Individualized volume CT dose index determined by cross-sectional area and mean density of the body to achieve uniform image noise of contrast-enhanced pediatric chest CT obtained at variable kV levels and with combined tube current modulation
    Goo HW [2011]
  • Feasibility of a radiation dose conserving CT protocol for myocardial function assessment
    Pursnani A [2014]
  • Feasibility and radiation dose of high-pitch acquisition protocols in patients undergoing dual-source cardiac CT
    Sommer WH [2010]
  • Estimation of the radiation exposure of a chest pain protocol with ECG-gating in dual-source computed tomography
    Ketelsen D [2009]
  • Dual-source CT for chest pain assessment
    Johnson TR [2008]
  • Does a combination of dose modulation with fast gantry rotation time limit CT image quality?
    Israel GM [2008]
  • Diagnostic image quality of a comprehensive high-pitch dual-spiral cardiothoracic CT protocol in patients with undifferentiated acute chest pain
    Bamberg F [2012]
  • Current trends in cardiac CT in children
    Goo HW [2013]
  • Clinical evaluation of automatic tube voltage selection in chest CT angiography
    Niemann T [2013]
  • CT coronary angiography: image quality with sinogramaffirmed iterative reconstruction compared with filtered backprojection
    Wang R [2013]
  • Assessment of right ventricular function by 16-detector-row CT : comparison with magnetic resonance imaging
    Koch K [2005]
  • Asian consortium on radiation dose of pediatric cardiac CT (ASCIREDCARD)
    Hui PKT [2017]
  • Age- and gender-specific estimates of cumulative CT dose over 5 years using real radiation dose tracking data in children
    Lee E [2015]
  • A low tube voltage technique reduces the radiation dose at retrospective ECG-gated cardiac computed tomography for anatomical and functional analyses
    Oda S [2011]