Uncertainties in neural network model based on carbon dioxide concentration for occupancy estimation

논문상세정보
    • 저자 Azimil Gani Alam Haolia Rahman 김중경 한화택
    • 제어번호 103571940
    • 학술지명 JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY
    • 권호사항 Vol. 31 No. 5 [ 2017 ]
    • 발행처 대한기계학회
    • 자료유형 학술저널
    • 수록면 2573-2580
    • 언어 English
    • 출판년도 2017
    • 등재정보 KCI등재
    • 판매처
    유사주제 논문( 0)

' Uncertainties in neural network model based on carbon dioxide concentration for occupancy estimation' 의 참고문헌

  • Ventilation control strategy using the supply CO2 concentration setpoint
    N. Nassif HVAC&R Research 11 2 239-262 [2005]
  • Simulations of indoor air quality and ventilation impacts of demand controlled ventilation in commercial and institutional buildings
    A. Persily 1-36 [2003]
  • Occupancy estimation based on CO2 concentration using dynamic network model
    H. Han - [2013]
  • Occupancy detection through an extensive environmental sensor network in an open-plan office building
    K. P. Lam 1452-1459 [2009]
  • Neural network forecasting for seasonal and trend time series
    G. P. Zhang European Journal of Operational Research 160 2 501-514 [2005]
  • Measurements of occupancy levels in multi-family dwellings-application to demand controlled ventilation
    D. Johansson Energy and Buildings 43 9 2449-2455 [2011]
  • Indoor environment management technology trends of building based on eco-energy
    KEITI 77- [2012]
  • Estimation of building occupancy level through environment signals deconvolution
    A. Ebadat Building System 13 1-8 [2013]
  • Effect of energy conservation by controlled ventilation : case study in a department store
    S. Ogasawara Energy and Buildings 2 1 3-8 [1979]
  • Control of ventilation to conserve energy while maintaining acceptable indoor air quality
    T. Kusuda ASHRAE Transactions 82 1169-1181 [1976]
  • CONTAMW 1.0 user manual : multizone airflow and contaminant transport analysis software
    W. S. Dols - [2000]
  • CO2-based DCV using 62. 1-2004
    S. T. Taylor ASHRAE Journal 48 67-75 [2006]
  • CO2-Based demand controlled ventilation under new ASHRAE Standard 62.1-2010: A case study for a gymnasium of an elementary school at west Lafayette
    M. O. Ng Indiana, Energy and Buildings 43 11 3216-3225 [2011]
  • CO2 monitoring for demand controlled ventilation in commercial buildings
    W. J. Fisk 42-43 [2010]
  • Applications of artificial neural-networks for energy systems
    S. A. Kalogirou Applied Energy 67 1-2 17-35 [2000]
  • An information technology enabled sustainability test-bed(ITEST)for occupancy detection through an environmental sensing network
    B. Dong Energy and Buildings 42 7 1038-1046 [2010]
  • An adaptive demand-controlled ventilation strategy with zone temperature reset for multi-zone airconditioning systems
    X. Xu Indoor and Build Environment 16 5 426-437 [2007]
  • A multisensor based occupancy estimation model for supporting demand driven HVAC operations
    Z. Yang Springsim 2 98-105 [2012]