' Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy' 의 주제별 논문영향력
논문영향력 선정 방법
논문영향력 요약
주제
  • 의학
  • detectivequantumefficiency(dqe)
  • electronic portal imaging device (epid)
  • modulation transfer function (mtf)
  • noise power spectrum (nps)
  • 변조전달함수
  • 양자검출 효율
  • 잡음전력스펙트럼
  • 전자포털영상장치
동일주제 총논문수 논문피인용 총횟수 주제별 논문영향력의 평균
7,656 0

0.0%

' Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy' 의 참고문헌

  • 텅스텐 엣지 블록을 이용하여 Megavoltage (MV) 영상의 질 평가
    민정환 의학물리 23 (3) : 154 ~ 161 [2012]
  • Validity of the line-pair bar-pattern method in the measurement of the modulation transfer function (MTF) in megavoltage imaging
    Gopal A Med Phys 35 : 270 ~ [2008]
  • Use of a line-pair resolution phantom for comprehensive quality assurance of electronic portal imaging devices based on fundamental imaging metrics
    Gopal A Med Phys 36 : 2006 ~ [2009]
  • The value of frequent treatment verification films in reducing localization error in the irradiation of complex fields
    Marks JE Cancer 37 : 2755 ~ [1976]
  • The influence of radiation therapy quality control on survival, response and sites of relapse in oat cell carcinoma of the lung:preliminary report of a Southwest Oncology Group study
    White JE Cancer 50 : 1084 ~ [1982]
  • Signal and noise in modulation transfer function determinations using the slit, wire and edge techniques
    Cunningham A Med Phys 19 : 1037 ~ [1992]
  • Performance of electronic portal imaging devices (EPIDs) used in radio-therapy: image quality and dose measurements
    Cremers F Med Phys 31 : 985 ~ [2004]
  • Performance of an Edge Block Used in a Configuration Detector: Image Quality Measurements
    Jung-Whan Min Journal of the Korean Physical Society 64 (5) : 732 ~ 739 [2014]
  • Localization error in the radiotherapy of Hodgkin's disease and malignant lymphoma with extended mantle fields
    Marks JE Cancer 34 : 83 ~ [1974]
  • Investigation of basic imaging properties in digital radiography. 1. Modulation transfer function
    Giger ML Med Phys 287 : 11 ~ [1984]
  • Immobilization errors: Some theoretical considerations
    Goitein M Radiology 117 : 407 ~ [1975]
  • Imaging performance of a digital storage phosphor system
    Hillen W Med Phys 14 : 744 ~ [1987]
  • Evaluation of the Modulation Transfer Function of Megavoltage X-rays
    Jung-Whan Min Journal of the Korean Physical Society 65 (11) : 1969 ~ 1975 [2014]
  • Evaluation of an algorithm for the assessment of the MTF using an edge method
    Greer PB Med Phys 27 : 2048 ~ [2000]
  • Evaluation of an Edge Method for Computed Radiography and an Electronic Portal Imaging Device in Radiotherapy: Image Quality Measurements
    Soon-Yong Son Journal of the Korean Physical Society 65 (11) : 1976 ~ 1984 [2014]
  • Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flatpanel imagers (AMFPIs) for diagnostic radiology
    Siewerdsen H Med Phys 24 : 71 ~ [1997]
  • Development and evaluation of a digital radiographic system based on CMOS image sensor
    Kim HK IEEE Trans Nucl Sci 3 : 662 ~ [2001]
  • CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가
    정회원 방사선기술과학 35 (2) : 109 ~ 117 [2012]
  • Comparison of Noise Power Spectrum Methodologies in Measurements by Using Megavoltage X-ray Energies
    민정환 Journal of the Korean Physical Society 60 (1) : 129 ~ 136 [2012]
  • An experimental comparison of detector performance for direct and indirect digital radiography systems
    Samei E Med Phys 30 : 608 ~ [2003]
  • Accurate MTF measurement in digital radiography using noise response
    Andrew G Med Phys 37 : 724 ~ [2010]
  • A simple method for determining the modulation transfer function in digital radiography
    Fujita H IEEE Trans Med Imaging 11 : 34 ~ [1992]
  • A practical method for detected quantum efficiency (DQE) assessment of digital mammography systems in the radiological environment
    Rogge F Proc SPIE 4682 : 645 ~ [2002]
  • A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    Samei E Med Phys 25 : 102 ~ [1998]