자기공명영상검사 시 26cm 이하 영상영역의 Multi-Transmit 기법의 유용성

논문상세정보
' 자기공명영상검사 시 26cm 이하 영상영역의 Multi-Transmit 기법의 유용성' 의 주제별 논문영향력
논문영향력 선정 방법
논문영향력 요약
주제
  • 의학
  • acquisition time reduction
  • acr phantom
  • acr 팬텀
  • multi-transmit
  • 획득시간감소
동일주제 총논문수 논문피인용 총횟수 주제별 논문영향력의 평균
7,590 0

0.0%

' 자기공명영상검사 시 26cm 이하 영상영역의 Multi-Transmit 기법의 유용성' 의 참고문헌

  • 고자장 MRI에서의 영상 영역에 대한 균질성
    김홍준 한국전자파학회 논문지 23 (1) : 96 ~ 100 [2012]
  • Whole-body MRI at high field, technical limits and clinical potential
    Schick, F Eur Radiol 15 (5) : 946 ~ 959 [2005]
  • Usefulness of turbo spinecho MR imaging in the evaluation of meniscal tears: comparison with a conventional spinecho sequence
    Escobedo EM AJR Am J Roentgenol 167 (5) : 1223 ~ 1227 [1996]
  • Ultra fast electromagnetic field computations for RF multitransmit techniques in high field MRI
    Van den Bergen B1 Phys Med Biol 54 (5) : 1253 ~ 1264 [2009]
  • The Evolution of Magnetic Resonance Imaging, 3T MRI in Clinical Applications
    Terry Duggan-Jahns Erad imaging [2008]
  • Simultaneous MRI acquisition of Both Knee Joints with Multitransmit Technology at 3T
    W. Wei Proc. Intl. Soc. Mag. Reson. Med [2011]
  • Scan time reduction in proton magnetic resonance spectroscopic imaging of the human brain
    Golay X Magn Reson Med 47 (2) : 384 ~ 387 [2002]
  • SENSE: sensitivity encoding for fast MRI
    Pruessmann KP Magn Reson Med 42 (5) : 952 ~ 962 [1999]
  • RF encoding using a multi-element parallel transmit system
    Katscher, U Magn Reson Med 63 (6) : 1463 ~ 1470 [2010]
  • On replacing the manual measurement of ACR phantom images performed by MRI technologists with an automated measurement approach
    Panych LP J Magn Reson Imaging [2015]
  • Multislice Double Inversion Pulse Sequence for Efficient Black-Blood MRI
    Song HK Magn Reson Med 47 (3) : 616 ~ 620 [2002]
  • MRI – From Picture to Proton
  • MRI Safety at 3T versus 1.5T
    Jerrolds, J Internet Journal of Radiology 11 (1) [2010]
  • Improved B1 homogeneity of 3 Tesla breast MRI using dual-source parallel radiofrequency excitation
    Rahbar H Magn Reson Imaging 35 (5) : 1222 ~ 1226 [2012]
  • Impact of 3.0 T Cardiac MR Imaging Using Dual-Source Parallel Radiofrequency Transmission with Patient-Adaptive B1 Shimming
    Jia H PLoS ONE 8 (6) [2013]
  • Imaging of the dielectric resonance effect in high field magnetic resonance imaging
    Mihara, H Journal of Applied Physics 97 (10) : 10R 305 ~ [2005]
  • High permittivity dielectric pads improve high spatial resolution magnetic resonance imaging of the inner ear at 7 T
    Brink WM1 Invest Radiol 49 (5) : 271 ~ 277 [2014]
  • Fast high-spatial-resolution MRI of the ankle with parallel imaging using GRAPPA at 3 T
    Bauer JS AJR Am J Roentgenol 189 (1) : 240 ~ 245 [2007]
  • Dual-Source Parallel Radiofrequency Excitation Body MR Imaging Compared with Standard MR Imaging at 3.0T
    Willinek WA1 Radiology 256 (3) : 966 ~ 975 [2010]
  • Dual-Source Parallel RF Transmission for Clinical MR Imaging of the Spine at 3.0 T, Intraindividual Comparison with Conventional Single-Source Transmission
    Nelles M Radiology 257 (3) : 743 ~ 753 [2010]
  • Common Hip Diseases and Their Imaging Studies
    Yoo KH J Korean Orthop US Soc 1 (1) : 40 ~ 49 [2008]
  • Clinical liver MRI at 3.0 Tesla using parallel RF transmission with patient-adaptive B1 shimming
    G. M. Kukuk Proc, Intl. Soc. Mag. Reson. Med [2009]
  • A specific absorption rate prediction concept for parallel transmission MR
    Graesslin I1 Magn Reson Med 68 (5) : 1664 ~ 1674 [2012]
  • 3.0 Tesla MR Clinical Application
    Son. C. H. Advanced Neuroimaging, Medical Postgraduates 33 (2) : 94 ~ 100 [2005]