Comparison of Bioabsorbable Suture Anchor Fixation on the Tibial Side for Anterior Cruciate Ligament Reconstruction Using Free Soft Tissue Graft -Experimental Laboratory Study on Porcine Bone

논문상세정보
' Comparison of Bioabsorbable Suture Anchor Fixation on the Tibial Side for Anterior Cruciate Ligament Reconstruction Using Free Soft Tissue Graft -Experimental Laboratory Study on Porcine Bone' 의 주제별 논문영향력
논문영향력 선정 방법
논문영향력 요약
주제
  • 의학
  • anterior cruciate ligament reconstruction
  • graft
  • suture anchor
  • tissuefixation
동일주제 총논문수 논문피인용 총횟수 주제별 논문영향력의 평균
7,612 2

3.5%

' Comparison of Bioabsorbable Suture Anchor Fixation on the Tibial Side for Anterior Cruciate Ligament Reconstruction Using Free Soft Tissue Graft -Experimental Laboratory Study on Porcine Bone' 의 참고문헌

  • Treatment of anterior cruciate ligament injuries, part 2
    Beynnon BD Am J Sports Med 33 1751-1767 [2005]
  • Transcutaneous migration of a tibial bioabsorbable interference screw after anterior cruciate ligament reconstruction
    Sassmannshausen G Arthroscopy 19 E133-E136 [2003]
  • The use of suture anchors in repair of the ruptured patellar tendon: a biomechanical study
    Bushnell BD Am J Sports Med 34 1492-1499 [2006]
  • The influence of supplementary tibial fixation on laxity measurements after anterior cruciate ligament reconstruction with hamstring tendons in female patients
    Hill PF Am J Sports Med 33 94-101 [2005]
  • The effect of graft stiffness on knee joint biomechanics after ACL reconstruction--a 3D computational simulation
    Suggs J Clin Biomech (Bristol, Avon) 18 35-43 [2003]
  • The EndoPearl device increases fixation strength and eliminates construct slippage of hamstring tendon grafts with interference screw fixation
    Weiler A Arthroscopy 17 353-359 [2001]
  • Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts
    Magen HE Am J Sports Med 27 35-43 [1999]
  • Soft-tissue interference fixation: bioabsorbable screw versus metal screw
    Brand JC Jr Arthroscopy 21 911-916 [2005]
  • Porcine tibia is a poor substitute for human cadaver tibia for evaluating interference screw fixation
    Nurmi JT Am J Sports Med 32 765-771 [2004]
  • Incidence and risk factors for injuries to the anterior cruciate ligament in National Collegiate Athletic Association football: data from the 2004-2005 through 2008-2009 National Collegiate Athletic Association Injury Surveillance System
    Dragoo JL Am J Sports Med 40 990-995 [2012]
  • Hamstring anterior cruciate ligament reconstruction: a comparison of bioabsorbable interference screw and endobutton-post fixation
    Ma CB Arthroscopy 20 122-128 [2004]
  • Effects of unilateral strength training and detraining on bone mineral density and content in young women: a study of mechanical loading and deloading on human bones
    Vuori I Calcif Tissue Int 55 59-67 [1994]
  • Effects of knee flexion angle at graft fixation on the outcome of anterior cruciate ligament reconstruction
    Asahina S Arthroscopy 12 70-75 [1996]
  • Effect of anterior cruciate ligament injury of the knee on bone mineral density of the spine and affected lower extremity: a prospective one-year follow-Up study
    Leppälä J Calcif Tissue Int 64 357-363 [1999]
  • Cross-pin femoral fixation: a new technique for hamstring anterior cruciate ligament reconstruction of the knee
    Clark R Arthroscopy 14 258-267 [1998]
  • Comparison of endoscopic and two-incision techniques for reconstructing a torn anterior cruciate ligament using hamstring tendons
    Howell SM Arthroscopy 15 594-606 [1999]
  • Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction
    Giurea M Am J Sports Med 27 621-625 [1999]
  • Comparative biomechanical study of the Ligament Plate and other fixation devices in ACL reconstruction
    Sim JA Int Orthop 33 1269-1274 [2009]
  • Biomechanical testing of hybrid hamstring graft tibial fixation in anterior cruciate ligament reconstruction
    Yoo JC KNEE 13 455-459 [2006]
  • Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: the impact of fixation level and fixation method under cyclic loading
    Scheffler SU Arthroscopy 18 304-315 [2002]
  • Biomechanical comparison of different fixation methods on the tibial side in anterior cruciate ligament reconstruction: a biomechanical study in porcine tibial bone
    Tetsumura S J Orthop Sci 11 278-282 [2006]
  • A prospective randomized study of patellar versus hamstring tendon autografts for anterior cruciate ligament reconstruction
    Jansson KA Am J Sports Med 31 12-18 [2003]
  • A new bioabsorbable interference screw: preliminary results of a prospective, multicenter, randomized clinical trial
    Benedetto KP Arthroscopy 16 41-48 [2000]
  • A long-term study of anterior cruciate ligament allograft reconstruction
    Almqvist KF Knee Surg Sports Traumatol Arthrosc 17 818-822 [2009]