치관 내 캔틸레버 양에 따른 내측 연결 형태 임플란트의 기계적 강도에 대한 연구

논문상세정보
' 치관 내 캔틸레버 양에 따른 내측 연결 형태 임플란트의 기계적 강도에 대한 연구' 의 주제별 논문영향력
논문영향력 선정 방법
논문영향력 요약
주제
  • cantilever
  • fatiguetest
  • internalconicaljointtypeimplant
동일주제 총논문수 논문피인용 총횟수 주제별 논문영향력의 평균
54 0

0.0%

' 치관 내 캔틸레버 양에 따른 내측 연결 형태 임플란트의 기계적 강도에 대한 연구' 의 참고문헌

  • Tissue intergrated prostheses. Osseointegration in clinical dentisty
    Carlsson GE Quintessence : 74 ~ 78 [1986]
  • Threedimensional finite element stress analysis of single implant restoration using different fixture and abutment screw diameters
    Kwon JH J Korean Acad Prosthodont 43 : 105 ~ 119 [2005]
  • Threedimensional finite element analysis on stress distribution of the mandibular implant-supported cantilever prostheses depending on the designs
    Ban JH J Korean Acad Prosthodont 47 : 70 ~ 81 [2009]
  • Survival studies of restorations: Criteria, Methods and analyses
    Leempoel PJB J Oral Rehabil 16 : 387 ~ 394 [1989]
  • Stress-absorbing elements in dental implants
    Van Rossen IP J Prosthet Dent 64 : 198 ~ 205 [1990]
  • Retrieval analysis of a blade implant after 231 months of clinical function
    Linkow LI Implant Dent 1 : 37 ~ 43 [1992]
  • Restorative dental materials
    Craig RG. Mosby : 60 ~ 61 [2002]
  • Osseointegration and its experimental back-ground
    Brånemark PI J Prosthet Dent 50 : 399 ~ 410 [1983]
  • Multicenter study of overdentures supported by Brånemark
    Jemt T Int J Oral Maxillofac Implants 7 : 513 ~ 522 [1992]
  • Multicenter retrospective analysis of the ITI implant system used for singletooth replacements : results of loading for 2 or more years
    Levine RA Int J Oral Maxillofac Implants 14 : 516 ~ 520 [1999]
  • Mechanics of the implant-abutment connection : a 8-degree taper compared to abutt joint connection
    Merz BR Int J Oral Maxillofac Implants 15 : 519 ~ 526 [2000]
  • Intra-osseous anchorage of dental prostheses: I. experimental studies
    Brånemark PI Scand J Plast Reconstr Surg 3 : 81 ~ 100 [1969]
  • Influence of implant-abutment interface design on bone and soft tissue levels around immediately placed and restored single-tooth implants : a randomized controlled clinical trial
    Pieri F Int J Oral Maxillofac Implants 26 : 169 ~ 178 [2011]
  • In vivo vertical forces on implants
    Richter EJ Int J Oral Maxillofac Implants 10 : 99 ~ 108 [1995]
  • In vitro differences of stress concentrations for internal and external hex implant-abutment connections: a short communication
    Maeda Y J Oral Rehabil 33 : 75 ~ 78 [2006]
  • Implant screw mechanics
    McGlumphy EA Dent Clinics North Am 42 : 71 ~ 89 [1998]
  • ISO/FDIS 14801 Dentistry-fatigue test for endosseous dental implants, Internal Organization for Standardization
    [2003]
  • Handbook of Mechanics, Materials and Structures
    Kirkwood WF Wiley : 320 ~ 328 [1985]
  • Fractures of the fixture component of an osseointegrated implant
    Morgan MJ Int J Oral Maxillofac Implants 8 : 409 ~ 414 [1993]
  • Forces and moments on Brånemark implants
    Rangert B Int J Oral Maxillofac implants 4 : 241 ~ 247 [1989]
  • Biomechanical considera tions when combining tooth-supported and implantsupported prostheses
    Weinberg LA Oral Surg Oral Med Oral Pathol 78 : 22 ~ 27 [1994]
  • Bending overload and implant fracture; a retrospective clinical analysis
    Rangert B Int J Oral Maxillofac Implants 10 : 326 ~ 334 [1995]
  • Basic biomechanics of dental implants in prosthetic dentistry
    Richter EJ J Prosthet Dent 61 : 602 ~ 609 [1989]
  • An in vitro evaluation of the strenght of an internal conical interface compared to a butt joint interface in implant design
    Norton MR Clin Oral Impl Res 8 : 290 ~ 298 [1997]
  • An analysis and management of fractured implants
    Balshi TJ Int J Oral Maxillofac Implants 11 : 660 ~ 666 [1996]
  • A 3-dimensional finite element analysis of tapered internal connection implant system(Avana SS Ⅲ􄠶)on different abutment connection
    Lee HS J Korean Acad Prosthodont 48 : 181 ~ 188 [2010]