An Adaptive Autoreclosure Scheme with Reference to Transient Stability for Transmission Lines

논문상세정보
' An Adaptive Autoreclosure Scheme with Reference to Transient Stability for Transmission Lines' 의 주제별 논문영향력
논문영향력 선정 방법
논문영향력 요약
주제
  • adaptive reclosure
  • autoreclosure
  • optimal reclosing time
  • phase-by-phase reclosure
  • transient stability emtp
동일주제 총논문수 논문피인용 총횟수 주제별 논문영향력의 평균
5 0

0.0%

' An Adaptive Autoreclosure Scheme with Reference to Transient Stability for Transmission Lines' 의 참고문헌

  • The Study on Real-Time Transient Stability Emergency Control in Power System
    L. Y. Qun Proc. 2002 IEEE CCECE Canadian Conf 1 : 138 ~ 143 [2002]
  • Predicting Future Behavior of Transient Events Rapidly Enough to Evaluate Remedial Control Options in Real-time
    S. Rovnyak IEEE Trans. on Power Systems 10 (3) : 1195 ~ 1203 [1995]
  • Power System Transient Stability Analysis using the Transient Energy Function Method, vol. I
    Fouad, V. Vittal Prentice Hall : 27 ~ 29 [1992]
  • Novel Techniques for Real Time Computing Critical Clearing Time SIME-B and CCS-B
    Hung Nguyen Dinh Journal of Electrical Engineering & Technology 8 (2) : 197 ~ 205 [2013]
  • Experimental Results of a Supplementary Technique for Auto-reclosing EHV/UHV Transmission Lines
    M. M. Eissa IEEE Trans. on Power Delivery 17 (3) : 702 ~ 707 [2002]
  • Effect of Sequential Reclosure of Multi-phase System Faults on Turbine-Generator Shaft Torsional Torques
    A. M. El-Serafi IEEE Trans. on Power Systems 6 (4) : 1380 ~ 1388 [1991]
  • Computation of Optimal Reclosure Time for Transmission Lines
    B. H. Zhang IEEE Trans. on Power Systems 17 (3) : 670 ~ 675 [2002]
  • Analysis of Transient Overvoltages within a 345kV Korean Thermal Plant
    Sang-Min Yeo Journal of Electrical Engineering & Technology 7 (3) : 297 ~ 303 [2012]
  • Analysis of Magnitude and Rate-of-rise of VFTO in 550 kV GIS using EMTP-RV
    서훈철 Journal of Electrical Engineering & Technology 8 (1) : 11 ~ 19 [2013]
  • An Alternative Approach to Adaptive Single Pole Auto-Reclosing in High Voltage Transmission Systems Based on Variable Dead Time Control
    S. P. Ahn IEEE Trans. on Power Delivery 16 (4) : 676 ~ 686 [2001]
  • Adaptive Three-phase Autoreclosure for Double-circuit Transmission Systems using Neural Networks
    Johns, A. T. Song, Y. H. Aggarwal, R. K. Proc. 1993 IEE Advances in Power System Control, Operation and Managements Conf : 389 ~ 392 [1993]
  • A Study on Adaptive Autoreclosure Scheme with Real-time Transient Stability
    Sung-Ik Jang Journal of Electrical Engineering & Technology 1 (1) : 8 ~ 15 [2006]
  • A Simple Direct Method for Fast Transient Stability Assessment of Large Power Systems
    Y. Xue IEEE Trans. on Power Systems 3 (2) : 400 ~ 412 [1988]
  • A New Method for Power System Transient Instability Detection
    L. Wang IEEE Trans. on Power Delivery 12 (3) : 1082 ~ 1089 [1997]
  • A Method For Capturing Optimal Reclosing Time of Transient Fault
    Y. C. Yuan Proc. 1998 POWERCON Conf : 18 ~ 21 [1998]
  • A Computer Model of the Secondary Arc in Single Phase Operation of Transmission Lines
    S. Goldberg IEEE Trans. on Power Delivery 4 (1) : 586 ~ 594 [1989]