치과용 임플란트의 안전성과 유효성에 대한 드릴 디자인의 효과

논문상세정보
' 치과용 임플란트의 안전성과 유효성에 대한 드릴 디자인의 효과' 의 주제별 논문영향력
논문영향력 선정 방법
논문영향력 요약
주제
  • cuttingtime
  • drilldesign
  • heatgeneration
  • initialstability
동일주제 총논문수 논문피인용 총횟수 주제별 논문영향력의 평균
25 1

0.0%

' 치과용 임플란트의 안전성과 유효성에 대한 드릴 디자인의 효과' 의 참고문헌

  • 새로 고안된 임플란트 드릴의 간소화된 드릴링 과정이 온도변화 및 절삭시간에 미치는 영향에 관한 연구
    윤지훈 대한치과재료학회지 39 (1) : 9 ~ 16 [2012]
  • Why do dental implants fail? Part II
    el Askary AS Implant Dent 8 : 265 ~ 277 [1999]
  • Why do dental implants fail? Part I
    el Askary AS Implant Dent 8 : 173 ~ 185 [1999]
  • Thermal injury to bone. A vital microscopic description of heat effects
    Eriksson RA Int J Oral Surg 1 : 115 ~ 121 [1982]
  • The effect of heat on bone regeneration : An experimental study in rabbit using the bone growth chamber
    Eriksson RA J Oral Maxillofac Surg 42 : 705 ~ 711 [1984]
  • Temperatures measured in human cortical bone when drilling
    Matthews LS J Bone Joint Surg 54 : 297 ~ 308 [1972]
  • Temperatures during drilling for the placement of implants using the osseointegration technique
    Eriksson RA J Oral Maxillofac Surg 44 : 4 ~ 7 [1986]
  • Temperature threshold levels for heat-induced bone tissue injury. A vital microscopic study in rabbit
    Eriksson RA J Prosthet Dent 50 : 101 ~ 107 [1983]
  • Risk Factor in Implant Dentisty
    Kim YG Well pub : 191 ~ 218 [2006]
  • Osseointegrated titanium implants. : Requirements for ensuring a long lasting, direct bone anchorage in man
    Albrektsson T Acta Orthop Scand 52 : 155 ~ 170 [1981]
  • Longitudinal clinical study on the efficacy of osseointegrated dental implants in partially edentulous Korean patients : an 8-years prospective study
    Han DH J Korean Acad Prosthodont 39 (6) : 698 ~ 708 [2001]
  • Long-term survival and success of oral implants in the treatment of full and partial arches : a 7-year prospective study with the ITI dental implant system
    Romeo E Int J Oral Maxillofac Implants 19 : 247 ~ 259 [2004]
  • Increase of temperature during osteotomy. In vitro and in vivo investigations
    Watcher R Int J Oral Maxillofac Surg 20 : 245 ~ 249 [1991]
  • ISO 14971 : 2007 Medical devices - Application of risk management for medical devices
    ISO ISO [2007]
  • Heat generation during implant site preparation : An in vitro study
    Cordioli G Int J Oral Maxillofac Implants 12 : 186 ~ 193 [1997]
  • Heat generation during implant drilling: the significance of motor speed
    Sharawy M J Oral Maxillofac Surg 60 (10) : 1160 ~ 1169 [2002]
  • Effects of irrigation temperature on heat control in vitro at different drilling depths
    Sener BC Clinical Oral Implants Research 20 : 294 ~ 298 [2009]
  • Effect of implant drill characteristics on heat generation in osteotomy sites : a pilot study
    Oh HJ Clinical Oral Implants Research 22 : 722 ~ 726 [2011]
  • Effect if surgical techniques on primary implant stability and periimplant bone
    Fanuscu MI J Oral Maxillofac Surg 65 : 2487 ~ 2491 [2007]
  • Clinical and radiographical evaluation of implant-supported fixed partial prostheses
    Seo JY J Korean Acad Prosthodont 44 (4) : 394 ~ 404 [2006]
  • An experimental investigation of the thermal properties of bone tissue and threshold levels for thermal injury
    Lundskog, J. Heat Scand J Plast Reconstr Surg 9 (suppl 9) : 1 ~ 80 [1972]