Design and Implementation of Solar PV for Power Quality Enhancement in Three-Phase Four-Wire Distribution System

논문상세정보
' Design and Implementation of Solar PV for Power Quality Enhancement in Three-Phase Four-Wire Distribution System' 의 주제별 논문영향력
논문영향력 선정 방법
논문영향력 요약
주제
  • fuzzy logic
  • neutral current
  • photo voltaic
  • power quality
  • total harmonic distortion
  • voltage source inverter
동일주제 총논문수 논문피인용 총횟수 주제별 논문영향력의 평균
419 0

0.0%

' Design and Implementation of Solar PV for Power Quality Enhancement in Three-Phase Four-Wire Distribution System' 의 참고문헌

  • methods and compensation characteristics of a series active filter for the neutral conductor
    I. Shigenori IEEE Transaction on Industrial Electronics 54 (1) [2007]
  • Three-phase four-wire shunt active filter control strategies
    M. Aredes IEEE Transactions on Power Electronics 12 (2) : 311 ~ 318 [1997]
  • New control algorithms for series and shunt three-phase four-wire active power filters
    Aredes IEEE Transactions on Power Delivery 10 (3) : 1649 ~ 1656 [1995]
  • Harmonic sources filtering approaches
    F. Z. Peng IEEE Industrial Application 7 (4) : 18 ~ 25 [2001]
  • Generalized instantaneous reactive power theory for three phase power system
    F. Z. Peng IEEE Transaction on Instrumentation and Measurement 45 (1) : 293 ~ 297 [1996]
  • Effectiveness of harmonic mitigation equipment for commercial buildings
    J. S. Lai IEEE Transactions on Industry Applications 33 (4) : 1104 ~ 1110 [1997]
  • Development of hybrid active power filter based on the adaptive fuzzy dividing frequency-control method
    A. Luo IEEE Transaction on Power Delivery 24 (1) : 424 ~ 432 [2009]
  • Development of active filter for three-phase fourwire system
    Ishihara Rec. SPC meeting of IEEJ (SPC-96-128) : 63 ~ 70 [1996]
  • Design of a neutral harmonic mitigator for three-phase four-wire distribution system
    P. Cheng IEEE/IAS Annual Meeting 1 : 164 ~ 171 [2001]
  • Control methods and compensation characteristics of a series active filter for a neutral conductor
    S. Inoue IEEE Transaction on Industry Applications 54 (1) [2007]
  • Compensation for Neutral Current Harmonics in a Three-Phase Four-Wire System by a Synchronous Machine
    Tadashi Fukami IEEE Transaction on Industry Applications 38 (5) [2003]
  • Characterization and compensation of harmonics and reactive power of residential and commercial loads
    J. A. Pomilio IEEE Transaction on Power Delivery 22 (2) : 1049 ~ 1055 [2007]
  • Analysis of zigzag transformer applying in the three-phase four-wire distribution power system
    H.L. Jou IEEE Transaction on Power Delivery 20 (2) [2005]
  • Analysis and design of a new active power filter to cancel neutral current harmonics in three-phase fourwire electric distribution systems
    P. N. Enjeti IEEE Transaction on Industrial Applications 30 : 1565 ~ 1572 [1994]
  • An optimizationbased method for selection of resonant harmonic filter branch parameters
    H. L. Ginn IEEE Transaction on Power Delivery 21 (3) : 1445 ~ 1451 [2006]
  • A survey of neutral currents in threephase computer power systems
    T. M. Gruzs IEEE Transactions on Industry Applications 26 (4) : 719 ~ 725 [1990]
  • A single-phase PWM rectifier with dc power active filter for fast dc output voltage control
    M. Saitou IEEJ Technical Meeting semiconductor Power Converter [2001]
  • A series active power filter adopting hybrid control approach
    Z. Wang IEEE Transaction on Power Electronics 16 (3) : 301 ~ 310 [2001]
  • A new approach to harmonic compensation in power systems-a combined system of shunt passive and series active filters
    F. Z. Peng IEEE Transaction on Industrial Applications 26 (6) : 983 ~ 990 [1990]
  • A fast series active filter using sliding mode control to correct and regulate unbalance voltage in threephase system
    Chatchanayuenyong American Journal of Engineering and Applied Sciences 2 (2) : 393 ~ 398 [2009]