적외선 체온의 진단 정확도 평가 연구: 체계적 문헌고찰

논문상세정보
' 적외선 체온의 진단 정확도 평가 연구: 체계적 문헌고찰' 의 주제별 논문영향력
논문영향력 선정 방법
논문영향력 요약
주제
  • 임상의학
  • fever
  • meta-analysis
  • sensitivity and specificity
  • thermometers
  • 메타분석
  • 민감도와특이도
  • 발열
  • 체온
동일주제 총논문수 논문피인용 총횟수 주제별 논문영향력의 평균
5,676 1

0.0%

' 적외선 체온의 진단 정확도 평가 연구: 체계적 문헌고찰' 의 참고문헌

  • 발 열
    김동수 Korean Journal of Pediatrics 50 (2) : 121 ~ 126 [2007]
  • 고막 체온계와 이마 체온계의 정확성 및 유용성에 대한 연구
    윤기욱 Korean Journal of Pediatrics 48 (8) : 820 ~ 825 [2005]
  • Tympanic membrane temperature as a measure of core temperature
    Childs C Archives of Disease in Childhood 80 (3) : 262 ~ 266 [1999]
  • Tympanic measurements: are they reliable in the critically ill? A clinical study of measures of agreement
    Moran JL Critical Care Medicine 35 (1) : 155 ~ 164 [2007]
  • The validity of the tympanic membrane thermometer in detecting fever of the children
    Lee WH Journal of the Korean Academy of Family Medicine 16 (8) : 531 ~ 536 [1995]
  • The accuracy of the T membrane thermometer in detecting fever in infants aged 3 months and younger in the emergency department setting
    Selfridge J Journal of Emergency Nursing 19 (2) : 127 ~ 130 [1993]
  • Reliability of infrared ear thermometry in the prediction of rectal temperature in older inpatients
    Smitz S Journal of Clinical Nursing 18 (3) : 451 ~ 456 [2009]
  • Reliability of infrared T thermometry in the detection of R fever in children
    Brennan DF Annals of Emergency Medicine 25 (1) : 21 ~ 30 [1995]
  • Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine
    Zweig MH Clinical Chemistry 39 (4) : 561 ~ 577 [1993]
  • Quantifying heterogeneity in a meta-analysis
    Higgins JP Statistics in Medicine 21 (11) : 1539 ~ 1558 [2002]
  • QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
    Whitting PF Annals of Internal Medicine 155 (8) : 529 ~ 536 [2011]
  • Properties of the summary receiver operating characteristic (SROC) curve for diagnostic test data
    Walter SD Statistics in Medicine 21 (9) : 1237 ~ 1256 [2002]
  • Principles and practical application of the receiver-operating characteristic analysis for diagnostic tests
    Greiner M Preventive Veterinary Medicine 45 (1-2) : 23 ~ 41 [2000]
  • Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement
    Moher D Annals of Internal Medicine 151 (4) : 264 ~ 269 [2009]
  • Medical device regulations revision No. 2014-142
    Ministry of Food and Drugs Safety
  • Measuring the accuracy of the infrared tympanic thermometer: correlation does not signify agreement
    Yaron M The Journal of Emergency Medicine 13 (5) : 617 ~ 621 [1995]
  • Limited accuracy and reliability of infrared axillary and aural thermometers in a pediatric outpatient population
    Jean-Mary MB Journal of Pediatrics 141 (5) : 671 ~ 676 [2002]
  • Limitations of forehead infrared body temperature detection for fever screening for severe acute respiratory syndrome
    Liu CC Infection Control and Hospital Epidemiology 25 (12) : 1109 ~ 1111 [2004]
  • Fever detection in under 5 children in a tertiary health facility using the infrared tympanic thermometer in the oral mode
    Edelu BO Italian Journal of Pediatrics 37 : 8 ~ [2011]
  • Evaluation of ear temperature measurements in a geriatric department
    Christensen PM Ugeskr Laeger 160 (36) : 5175 ~ 5177 [1998]
  • Ear thermometer not an adequate alternative to rectal thermometer
    Duberg T Lakartidningen 104 (19) : 1479 ~ 1482 [2007]
  • Does tympanic temperature measure up?
    Wells N The American Journal of Maternal/ Child Nursing 20 : 95 ~ 100 [1995]
  • Development of standard and improvement of reliability in body temperature measurement
    Park CW Journal of the Korean Society for Precision Engineering 24 (9) : 32 ~ 36 [2007]
  • Comparison of rectal temperature with axillary and tympanic temperature
    Hwang JS Journal of Korean Academy of Korean Fundamentals of Nursing 4 (2) : 351 ~ 358 [1997]
  • Comparison of rectal and infrared ear temperatures in older hospital inpatients
    Smitz S Journal of American Geriatric Society 48 (1) : 63 ~ 66 [2000]
  • Comparison of axillary and infrared tympanic membrane thermometry in a pediatric oncology outpatient setting
    Androkites AL Journal of Pediatric Oncology Nursing 15 : 216 ~ 222 [1998]
  • Comparison of a tympanic thermometer to rectal and oral thermometers in a pediatric emergency department
    Chamberlain JM Clinical Pediatrics 30 (4) : 24 ~ 29 [1991]
  • Cochrane handbook for systematic reviews of diagnostic test accuracy version 1.0
  • Can training improve the results with infrared tympanic thermometers?
    Petersen MH Acta Anaesthesiologica Scandinavica 41 (8) : 1066 ~ 1070 [1997]
  • Can ear temperature measurement be used in a hospital?
    Nordås TG Tidsskr Nor Laegeforen 125 (20) : 2763 ~ 2765 [2005]
  • Accuracy of tympanic temperature readings in children under 6 years of age
    Lanham DM Pediatric Nursing 25 (1) : 39 ~ 42 [1999]
  • Accuracy of temperature measurements, nursing time for measuring temperature and the validity of fever detection
    Sohng KY Journal of Korean Academy of Korean Fundamentals of Nursing 5 (1) : 33 ~ 45 [1998]
  • Accuracy of a noninvasive temporal artery thermometer for use in infants
    Greenes DS Archives of Pediatrics & Adolescent Medicine 155 (3) : 376 ~ 381 [2001]
  • A readers' guide to the interpretation of diagnostic test properties: clinical example of sepsis
    Fischer JE Intensive Care Medicine 29 (7) : 1043 ~ 1051 [2003]
  • A comparison of the use of tympanic, axillary and rectal thermometers in infants
    Wilshaw R Journal of Pediatric Nursing 14 (2) : 88 ~ 93 [1999]
  • A comparison of oral, tympanic, and rectal temperature measurement in the elderly
    Varney SM Journal of Emergency Medicine 22 (2) : 153 ~ 157 [2002]
  • A comparison between infrared tympanic thermometry, oral and axilla with rectal thermometry in neutropenic adults
    Dzarr AA European Journal of Oncology Nursing 13 (4) : 250 ~ 254 [2009]
  • A comparative study of infrared tympanic thermometry and rectal mercury thermometry
    Valle PC Scandinavian Journal of Infectious Disease 31 (1) : 105 ~ 106 [1999]