박사

Development and performance verification of post-tensioned anchor for unbonded single-strand tendon

조아서 2020년
논문상세정보
' Development and performance verification of post-tensioned anchor for unbonded single-strand tendon' 의 주제별 논문영향력
논문영향력 선정 방법
논문영향력 요약
주제
  • 건물
  • Anchor
  • Encapsulation
  • Performance
  • Post-tensioning
  • Slab
  • Unbonded
  • deflection
  • develop-ment
  • 개발
  • 비부착
  • 성능
  • 슬래브
  • 정착구
  • 처짐
  • 캡슐화
  • 포스트텐션
동일주제 총논문수 논문피인용 총횟수 주제별 논문영향력의 평균
3,244 0

0.0%

' Development and performance verification of post-tensioned anchor for unbonded single-strand tendon' 의 참고문헌

  • [66] PJM, “Review of Operating Metrics”, Feb. 2019.
  • What Is Post-Tensioing ? : Post-Tensioning Institute
    [2000]
  • Weldability of Spheroidal Graphite Ductile Cast Iron Using Ni / Ni-Fe Electrodes
    45 ( 5 ) , 334- 338 [2009]
  • VSL Strand Post-Tensioning Systems : VSL International Ltd
    [2015]
  • Utjecaj Broja Nodula na Žilavost Feritnog Nodularnog Lijeva .
    50 ( 4 ) , 231-238 . ( in Croatian ) [2008]
  • Uncoated Stress-Relieved Steel Wires and Strands for Prestressed Concrete
    [2019]
  • Unbonded Post-Tensioning Floor System Technology
    15 ( 2 ) , 90-101 . ( in Korean ) [2003]
  • The History of Prestressed Concrete : 1888 to 1963
    [2009]
  • Surface Texture Control ( SAE J449 )
    [2011]
  • Standard Specification for Low-Relaxation , Seven-Wire Steel Strand for Prestressed Concrete ( ASTM A416M )
    [2018]
  • Standard Specification for Ductile Iron Castings ( ASTM A536 )
    [1984]
  • Standard Practice for Evaluating Degree of Rusting on Painted Steel Surfaces ( ASTM D610 )
    [2008]
  • Standard Concrete Specification and Commentary : Korea Concrete Institute
    [2010]
  • Spheroidal Graphite IronCastings ( SPS-KFCA-D4302-5016 )
    [2017]
  • Specifications for Unbonded Post-Tensioning Tendons
    38 ( 10 ) , 35-39 . [2016]
  • Specifications for StructuralConcrete for Buildings ( ACI 301 )
    [1989]
  • Specifications for StructuralConcrete ( ACI 301 )
    [2016]
  • Specification for Unbonded Single-Strand Tendons ( ACI 423.6 ) andCommentary ( ACI 423.6R )
    [2001]
  • Specification for Unbonded Single-Strand Tendon Materials ( ACI 423.7 )
    [2014]
  • Seismic Tests of RC Exterior Beam-Column Joints with HighStrength Materials and Unbonded Tendons
    [2016]
  • S. D. andCovino , B. S.
    [2005]
  • Recommendations forConcrete Members Prestressed with Unbonded Tendons ( ACI 423.3R )
    [1996]
  • Recommendations forConcrete Members Prestressed with Unbonded Tendons ( ACI 423.3R )
    [2005]
  • Recommendations forConcrete Members Prestressed with Unbonded Tendons ( ACI 423.3R )
    [2017]
  • PrestressedConcrete ; Design andConstruction
    2 ed [1964]
  • Prediction ofCreep , Shrinkage , and Temperature Effects inConcrete Structures ( ACI 209R )
    [1992]
  • Precision SURE-LOCK® Post-Tension Anchorage andCoupling System and the HSM Post-Tensioning Anchorage System ( ESR-2381 ) : ICC Evaluation Service , LLC .
    [2018]
  • Post-Tensioning in Building Structures
    33 ( 4 ) , 48-54 . [2007]
  • Post-Tensioning Manual ( TAB.1 ) ( 6 ed . ) : Post-Tensioning Institute
    [2006]
  • Piano Wire Rods
    [2018]
  • PWC. (2012). Big Data-The next frontier for innovation, Pricewaterhouse Coopers, pp.2-3.
  • PTI. (2010). Specification for Unbonded Single Strand Tendons (PTI M10.2): PostTensioning Institute.
  • P. H.
    No . 375999
  • Modeling and Analysis of the Rapidly Resolidified Layer of SG Cast Iron in the EDM Process through the Response Surface Methodology
    182 ( 1-3 ) , 525-533 [2007]
  • Millis, K. D., Gagnebin, A. P., and Pilling, N. B. (1949). US Patent No. 2485761.
    No . 2485761 . [1949]
  • Microstructure and Deformation Behaviour of Ductile Iron under Tensile Loading ( Doctoral Dissertation )
    [2015]
  • Mechanical Properties of SG-Iron with Different Matrix Structure
    36 ( 5 ) , 1293-1300 [2001]
  • Maturity Computer for Controlled Curing and Hardening of Concrete
    1 , 21-25 . ( in Danish ) [1977]
  • Mathematical Characterization of the Tensile Deformation Curve of Cast Iron Materials
    [2018]
  • Mapping Atmospheric Corrosion in Coastal Regions : Methods and Results
    2 ( 1 ) [2012]
  • Load-Carrying Performance and Hydrostatic Tests of Encapsulated Anchor Systems for Unbonded Post-Tensioning SingleStrands
    12 ( 1 ) .
  • Load Transfer Test of Spirally Reinforced Anchorage Zone for Banded Tendon Group .
    17 ( 1 ) , 59-67 . ( in Korean ) [2017]
  • Kchaou, H., Benbettaïeb, N., Jridi, M., Abdelhedi, O., Karbowiak, T.,Brachais,C.-H., . . . Nasri, M. (2018). Enhancement of structural, functional and antioxidant properties of fish gelatin films using Maillard reactions. Food Hydrocolloids, 83, 326-339.
  • KR Patent No . 10- 20180027840
    [2018]
  • Integrated Solutions for Building Prestressing by PostTensioning : Soletanche Freyssinet
    [2014]
  • Hydrostatic Test for Encapsulated Systems
    [2014]
  • Guideline for European Technical Approval of Post-Tensioning Kits for Prestressing of Structures ( ETAG 013 ) : European Organisation for Technical Approvals
    [2002]
  • GTI Zero Void® Post-Tensioning System ( ESR-2515 ) : ICC Evaluation Service , LLC .
    [2019]
  • Freyssinet, E. and Seailles, J. (1937). US Patent No. 2080074.
    No . 2080074 [1937]
  • Experimental Study of 2-Span Continuous Beams with 2400 MPa Unbonded Tendons
    [2018]
  • Evaluation of Strength and Stiffness Gain of Concrete at Early-Ages
    22 ( 2 ) , 237-245 . ( in Korean ) [2010]
  • European Technical Approval ETA-08/0012 : Tensacciai PostTensioning System : European Organisation for Technical Approvals
    [2013]
  • Erosion of Ductile Cast Iron with Quartz Particles . Tehnički Vjesnik : Znanstveno-Stručni Časopis Tehničkih Fakulteta Sveučilišta U Osijeku
    17 ( 1 ) , 17-22 . ( in Croatian ) [2010]
  • Encapsulated Post-Tensioned Concrete for Corrosive and NonCorrosive Environments
    [2010]
  • Dschaak, Z. A., & Juntunen, C. L. (2018). Stigma, substance use, and help-seeking attitudes among rural and urban individuals. Journal of Rural Mental Health, 42(3-4), 184-195.
  • Development and Performance Test for Unbonded Post-Tensioned Anchor
    27 ( 1 ) , 11-20 . ( in Korean ) [2015]
  • Development and Application of Anchor for Unbonded Tendon
    27 ( 3 ) , 28-31 . ( in Korean ) [2015]
  • DYWIDAG Bonded Post-Tensioning Systems Using Strands : DYWIDAG–Systems International
    [2004]
  • Criteria for Machinability Evaluation of Compacted Graphite Iron Materials : Design and Production Planning Perspective on Cylinder Block Manufacturing ( Doctoral Dissertation )
    [2011]
  • Code Requirements for Environmental Engineering Concrete Structures and Commentary ( ACI 350
    [2001]
  • Code Requirements for Environmental Engineering Concrete Structures and Commentary ( ACI 350
    [2006]
  • Building Code Requirements for Structural Concrete ( ACI 318 ) and Commentary ( ACI 318R )
    [1989]
  • Building Code Requirements for Structural Concrete ( ACI 318 ) and Commentary ( ACI 318R )
    [2019]
  • Bridge Design Specifications ( LRFD-8 ) : American Association of State Highway and Transportation Officials
  • Behavior of Unbonded Posttensioning Monostrand Anchorage Systems under Monotonic Tensile Loading
    55 ( 1 ) , 97-117 . [2010]
  • Behavior and Design of Unbonded PostTensioning Strand/Anchorage Systems for Seismic Applications ( Report # NDSE-09- 02 )
    [2009]
  • Application of Post-Tensioning in Multi-Storey Buildings .
    6 ( 3 ) , 242-245 . [2017]
  • Anchorage Zone Reinforcement for Unbonded Post-Tensioned Circular Anchorage for Single Tendon .
    18 ( 3 ) , 117-124 . ( in Korean ) [2018]
  • An Experimental Study on the Performance of One-Way Slab Using Unbonded Post-Tensioned Anchorage for Single Tendon .
    19 ( 1 ) , 45-51 . ( in Korean ) [2019]
  • Amsysco Unbonded Post-Tensioning Systems ,
    [2010]
  • Alga Slab - Solutions for Post-Tensioned Slab : Alga S.p.A. ( in Italian ) Allen , A. H. ( 1981 ) . An Introduction to Prestressed Concrete
    [2001]
  • Acceptance Criteria for Post-Tensioning Anchorages and Couplers of Prestressed Concrete ( ICC-ES AC303 ) : ICC Evaluation Service , LLC .
    [2011]
  • ASM Handbook : Fatigue and Fracture
    [1996]
  • AIR(2013), Smarter Balanced Assessment Consortium: Cognitive Laboratories Technical Report
  • ACI and PTI Requirements for Encapsulation Systems
    5 ( 1 ) , 49-54 . [2007]
  • AASHTO LRFD Bridge Construction Specifications ( LRFDCONS-4 )
  • A Study on the Wedge-Type Anchorage Slip of Prestressed Concrete Structures .
    11 ( 11 ) , 193-201 . ( in Korean ) [1995]
  • A Short History of Unbonded Post-Tensioning Specifications
    [2001]
  • A Review on Performance Test Methods for Post-Tensioned Anchor
    30 ( 1 ) , 7-8 . ( in Korean )
  • A Design Engineer 's Digest of Ductile Iron ( 9 ed . ) : QIT-Fer et Titane Incorporated
    [2010]
  • 60. Pternea, M., Kepaptsoglou, K., &Karlaftis, M. G. (2015). Sustainable urban transit network design. Transportation Research Part A: Policy and Practice, 77, 276-291.