박사

하이텐션스프링을 이용한 제진시스템의 내진성능에 관한 연구 = A Study on Seismic Performance of Vibration Control System Using High-Tension Spring

정명철 2019년
논문상세정보
' 하이텐션스프링을 이용한 제진시스템의 내진성능에 관한 연구 = A Study on Seismic Performance of Vibration Control System Using High-Tension Spring' 의 주제별 논문영향력
논문영향력 선정 방법
논문영향력 요약
주제
  • 건물
  • 내진보강
  • 스프링
  • 제진시스템
  • 지진
동일주제 총논문수 논문피인용 총횟수 주제별 논문영향력의 평균
1,540 0

0.0%

' 하이텐션스프링을 이용한 제진시스템의 내진성능에 관한 연구 = A Study on Seismic Performance of Vibration Control System Using High-Tension Spring' 의 참고문헌

  • 철근콘크리트 속빈 단면 보의 곡률연성지수 특성,
    이형준 한국산학기술학회, 14(12), 6542-6549 [2013]
  • http://www
    기상청 kma.go.kr/communication/webzine/earthquakeyearly.jsp
  • Xiang Yun, Leroy Gardner (2017). "Stress-strain curves for hot-rolled steels," Journal of Constructional Steel Research, 133, 36-46
  • Umemura, H. editor. Earthquake Resistant Design of Reinforced Concrete Buildings, Accounting for the Dynamic Effects of Earthquakes. Giho-do Publishing Co., Japan, 1973 (in Japanese).
  • Newmark, N.W. A method of computation for structural dynamics. Journal of the Structural Division ASCE 1959; 85: 67-94.
  • Murakami, M. and Penzien,J. Nonlinear response spectra for probabilistic seismic design and damage assessment of reinforced concrete structures. Report No. EERC 75-38, University of California, Berkeley, 1975.
  • Murakami, M. Required strength for probabilistic seismic design and damage assessment of reinforced concrete structures. The Seventh World Conference on Earthquake Engineering, vol. 4, Istanbul, Turkey, 1980; 211-218.
  • Miyazawa, M., Ogura, K., Yamada, M., and Fukushima, J. Earthquake response of low-rise reinforced concrete buildings with structural walls. Proceedings of the Architectural Institute of Japan Annual Convention, 1976; 1325-1326 (In Japanese).
  • Maeda, M., Bunno, M., and Nagata, M. Damage level classification of reinforced concrete buildings based on member residual seismic performance: Part 1 - Basic concepts of classification, Proceedings of the Architectural Institute of Japan Annual Convention, 2000; C-2; 17-18 (In Japanese).
  • Lee, K.S., Nakano, Y., Kumazawa, H., and Okada, T., (1996). “Seismic Capacity of Reinforced Concrete Buildings Damaged by the 1995 Hyogo-ken Nambu Earthquake (Seismic Capacity of Reinforced Concrete Buildings on Awaji Island),” Journal of Structural Engineering, Architectural Institute of Japan, Japan Society of Civil Engineers, Vol. 42B (in Japanese).
  • Lee, K.S., (2010). “Seismic Capacity Requirements for Low-rise Reinforced Concrete Buildings Controlled by both Shear and Flexure,” Journal of Advanced Concrete Technology, 8(1), 75–91.
  • Lee, K.S. et al., (2010). “A Practical Rapid Screening Method for Evaluating the Seismic Capacity of Low-rise Reinforced Concrete Buildings,” Journal of Advanced Concrete Technology, 9(3), 301-314.
  • Kubo, T., Akagi, T., Ueno, K., and Etawa, M. A. E. Seismic capacity of reinforced concrete buildings constituted of flexural and shear failure members: Seismic capacity evaluation of seismic screening standards in Japan. Proceedings of the Tenth Japan Earthquake Engineering Symposium, 1998; 3273-3278 (in Japanese).
  • Kubo, T. and Etawa, M. A. E. Seismic capacity of reinforced concrete buildings evaluated based on the basic structural index and nonlinear seismic analysis: Focused on buildings controlled by flexure. Proceedings of the Architectural Institute of Japan Annual Convention, 1999; C-2; 269-270 (in Japanese).
  • Japan Building Disaster Prevention Association. Standard for Damage Level Classification, Tokyo, Japan, 2001 (in Japanese).
  • Japan Building Disaster Prevention Association : Standard for Damage Level Classification, Tokyo, Japan(in Japanese), 2001.
  • Hisano, M. and Okada, T. Earthquake response of low-rise reinforced concrete buildings with structural walls: SDOF parallel wall-frame system. Proceedings of the Architectural Institute of Japan Annual Convention, 1975; 481-482 (In Japanese).
  • Hakuno et al., Hybrid Test Manual, Institute of Industrial Science, The University of Tokyo, 1988.
  • Fukuda, Y. Study on the restoring force characteristics of reinforced concrete buildings. Proceedings of the Kanto District Symposium, the Architectural Institute of Japan, no. 40, 1969; 121-124 (in Japanese).
  • Federal Emergency Management Agency, FEMA 356: Prestandard and commentary for Seismic Rehabilitation of Buildings. Washington D.C., 2000.
  • Federal Emergency Management Agency, FEMA 310 : Handbook for Seismic Evaluation of Buildings - A Prestandard, Washington D.C., 1998.
  • Etawa, M. A. E, Kubo, T., and Ueno, K. Seismic capacity of reinforced concrete buildings evaluated based on the basic structural index and nonlinear seismic analysis: Focused on buildings controlled by shear. Proceedings of the Architectural Institute of Japan Annual Convention, 1998; C-2; 63-64 (in Japanese).
  • ACI Commitee 318-02, Building Code Requirements for Reinforced Concrete. 日本建築學會, “鐵筋 コソクリ―ト 構造計算規準⋅同解說”, 1999.
  • , , “1980년대 국내 철근콘크리트 학교건물의 내진 안 전성 평가에 관한 연구,” 한국 구조물진단유지관리공학회, 13(5)
    김용인, 위정두 이강석 이현호 149-159 (In Korean) [2009]