박사

3차원 프린팅 기술로 제작한 폐 모형을 이용한 사이버나이프 종양추적방사선치료의 정확도 검증 : Verification of accuracy of CyberKnife tumor-tracking radiation therapy using a lung phantom created by precision 3D printing technology

정진홍 2015년
논문상세정보
' 3차원 프린팅 기술로 제작한 폐 모형을 이용한 사이버나이프 종양추적방사선치료의 정확도 검증 : Verification of accuracy of CyberKnife tumor-tracking radiation therapy using a lung phantom created by precision 3D printing technology' 의 주제별 논문영향력
논문영향력 선정 방법
논문영향력 요약
주제
  • 3d lung phantom
  • 3d printing technology
  • cyberknife
  • stereotactic ablative radiotherapy
  • total tracking error
  • xsight lung tracking system
동일주제 총논문수 논문피인용 총횟수 주제별 논문영향력의 평균
30 0

0.0%

' 3차원 프린팅 기술로 제작한 폐 모형을 이용한 사이버나이프 종양추적방사선치료의 정확도 검증 : Verification of accuracy of CyberKnife tumor-tracking radiation therapy using a lung phantom created by precision 3D printing technology' 의 참고문헌

  • van der Voort van Zyp NC, Prevost JB, Hoogeman MS, Praag J, van der Holt B,Levendag PC, et al. Stereotactic radiotherapy with real-time tumor tracking for nonsmallcell lung cancer: clinical outcome. Radiother Oncol 2009;91(3):296-300.
  • Trumm CG, Haussler SM, Muacevic A, Stahl R, Stintzing S, Paprottka PM, et al.32CT fluoroscopy-guided percutaneous fiducial marker placement for CyberKnifestereotactic radiosurgery: technical results and complications in 222 consecutiveprocedures. J Vasc Interv Radiol 2014;25(5):760-8.
  • Timmerman R, Paulus R, Galvin J, Michalski J, Straube W, Bradley J, et al.Stereotactic body radiation therapy for inoperable early stage lung cancer. JAMA2010;303(11):1070-6.
  • Solda F, Lodge M, Ashley S, Whitington A, Goldstraw P, Brada M. Stereotacticradiotherapy (SABR) for the treatment of primary non-small cell lung cancer;systematic review and comparison with a surgical cohort. Radiother Oncol2013;109(1):1-7.
  • Schweikard A, Shiomi H, Adler J. Respiration tracking in radiosurgery. Med Phys2004;31(10):2738-41.
  • Schweikard A, Glosser G, Bodduluri M, Murphy MJ, Adler JR. Robotic motioncompensation for respiratory movement during radiosurgery. Comput Aided Surg2000;5(4):263-77.
  • Pepin EW, Wu H, Zhang Y, Lord B. Correlation and prediction uncertainties in thecyberknife synchrony respiratory tracking system. Med Phys 2011;38(7):4036-44.
  • Nuyttens JJ, Prevost JB, Praag J, Hoogeman M, Van Klaveren RJ, Levendag PC, etal. Lung tumor tracking during stereotactic radiotherapy treatment with theCyberKnife: Marker placement and early results. Acta Oncol 2006;45(7):961-5.
  • Nioutsikou E, Seppenwoolde Y, Symonds-Tayler JR, Heijmen B, Evans P, Webb S.Dosimetric investigation of lung tumor motion compensation with a roboticrespiratory tracking system: an experimental study. Med Phys 2008;35(4):1232-40.
  • Naruke T, Goya T, Tsuchiya R, Suemasu K. Prognosis and survival in resected lungcarcinoma based on the new international staging system. J Thorac Cardiovasc Surg1988;96(3):440-7.
  • Lu XQ, Shanmugham LN, Mahadevan A, Nedea E, Stevenson MA, Kaplan I, et al.Organ deformation and dose coverage in robotic respiratory-tracking radiotherapy.Int J Radiat Oncol Biol Phys 2008;71(1):281-9.
  • Jung KW, Won YJ, Kong HJ, Oh CM, Lee DH, Lee JS. Cancer statistics in Korea:incidence, mortality, survival, and prevalence in 2011. Cancer Res Treat2014;46(2):109-23.
  • Ionascu D, Jiang SB, Nishioka S, Shirato H, Berbeco RI. Internal-externalcorrelation investigations of respiratory induced motion of lung tumors. Med Phys2007;34(10):3893-903.
  • Imura M, Yamazaki K, Shirato H, Onimaru R, Fujino M, Shimizu S, et al. Insertionand fixation of fiducial markers for setup and tracking of lung tumors inradiotherapy. Int J Radiat Oncol Biol Phys 2005;63(5):1442-7.
  • Hoogeman M, Prevost JB, Nuyttens J, Poll J, Levendag P, Heijmen B. Clinicalaccuracy of the respiratory tumor tracking system of the cyberknife: assessment byanalysis of log files. Int J Radiat Oncol Biol Phys 2009;74(1):297-303.
  • Fu D, Kahn R, Wang B, Wang H, Mu Z, Park J, et al. Xsight Lung Tracking System:33A Fiducial-Less Method for Respiratory Motion Tracking. In: Urschel H, editor.Robotic Radiosurgery Treating Tumors that move with Respiration: Springer; 2007.p. 265-80.
  • Fakiris AJ, McGarry RC, Yiannoutsos CT, Papiez L, Williams M, Henderson MA, etal. Stereotactic body radiation therapy for early-stage non-small-cell lung carcinoma:four-year results of a prospective phase II study. Int J Radiat Oncol Biol Phys2009;75(3):677-82.
  • Collins BT, Erickson K, Reichner CA, Collins SP, Gagnon GJ, Dieterich S, et al.Radical stereotactic radiosurgery with real-time tumor motion tracking in thetreatment of small peripheral lung tumors. Radiat Oncol 2007;2:39.
  • Brown WT, Wu X, Fayad F, Fowler JF, Amendola BE, Garcia S, et al. CyberKniferadiosurgery for stage I lung cancer: results at 36 months. Clinical lung cancer2007;8(8):488-92.
  • Bibault JE, Prevost B, Dansin E, Mirabel X, Lacornerie T, Lartigau E. Image-guidedrobotic stereotactic radiation therapy with fiducial-free tumor tracking for lungcancer. Radiat Oncol 2012;7:102.
  • Baumann P, Nyman J, Hoyer M, Wennberg B, Gagliardi G, Lax I, et al. Outcome ina prospective phase II trial of medically inoperable stage I non-small-cell lungcancer patients treated with stereotactic body radiotherapy. J Clin Oncol2009;27(20):3290-6.
  • Adebonojo SA, Bowser AN, Moritz DM, Corcoran PC. Impact of revised stageclassification of lung cancer on survival: a military experience. Chest1999;115(6):1507-13.
  • ?1. Ferlay J, Shin HR, Bray F, Forman D, Mathers C, Parkin DM. Estimates ofworldwide burden of cancer in 2008: GLOBOCAN 2008. Int J Cancer2010;127(12):2893-917.